Side by side

Clorox 11010 vs Honeywell HPA300 Compared: Clorox offers particle Auto, Honeywell offers more smoke CADR at its manual Turbo

Quick verdict

Go with the Clorox 11010 if you want PM2.5-triggered fan changes and its 206 CFM maximum smoke rating fits your room target. Keep in mind that Auto varies the fan, so it cannot guarantee that rate. The HPA300 is the choice when your target is above 206 CFM and no higher than 300 CFM, provided you will set manual Turbo and can live with the sound. Either one needs a dry, open spot where you can still service it. Clorox should stay away from greasy kitchens, open fires and oil or chemicals, and Honeywell from damp locations and combustible fumes. Nothing here proves quiet-setting output or hazardous-gas protection, and neither unit combines particle Auto with capacity above 206 CFM.

Before you buy

Why, and what it costs you

A bigger room can make the extra capacity a requirement

Take an 18 by 20 by 8-foot room and a chosen target of five filtered-air changes per hour. That requires 240 CFM. HPA300 passes the sizing calculation on manual Turbo, and Clorox’s 206 CFM maximum does not. At 15 by 15 by 8 feet the same target drops to 150 CFM and both maximum ratings qualify, so capacity no longer decides alone. Neither example establishes quiet-speed output, ventilation or a health result.

Where this comes from

Published smoke CADR figures are compared here at maximum fan speed, and the room dimensions and five-change target are assumptions stated up front. Actual particle levels still depend on room mixing, open doors or windows, ongoing sources and the filters.

The catch

Clorox Large Room True HEPA

In Auto the fan can run below maximum, so the published 206 CFM smoke CADR is no promise of continuous Auto output. Alexa features listed for the 11011 do not carry over to the 11010.

The catch

Honeywell HPA300

You only get the 300 CFM smoke rating at maximum speed. HPA300 starts on Low, so you have to select Turbo yourself. Neither quiet-setting capacity nor automatic particle response is established.

Clorox Large Room True HEPA

Clorox Large Room True HEPA

Why pick it
  • You care about PM2.5-triggered fan changes, and 206 CFM at maximum speed covers your room target. Clorox’s Auto reacts to what the sensor reads. It does not guarantee maximum flow or monitor the safety of the whole room. Set it on a dry, level surface with clear airflow and room to reach the filter, away from greasy kitchens, open fires and oil or chemicals. Routine care still applies.
The catch
In Auto the fan can run below maximum, so the published 206 CFM smoke CADR is no promise of continuous Auto output. Alexa features listed for the 11011 do not carry over to the 11010.
See price & reviews on Amazon
Honeywell HPA300

Honeywell HPA300

Why pick it
  • Your smoke-CADR target is above 206 CFM but not above 300 CFM, and you are willing to switch the HPA300 to manual Turbo and live with the noise. Its Low startup setting does not reach that rating. Stand it upright in a dry spot with the grilles clear, the front accessible for filters and a direct wall outlet, away from damp locations and combustible fumes. You will still need to replace filters.
The catch
You only get the 300 CFM smoke rating at maximum speed. HPA300 starts on Low, so you have to select Turbo yourself. Neither quiet-setting capacity nor automatic particle response is established.
See price & reviews on Amazon

We may earn a commission from qualifying Amazon purchases. How we make money

Comparison updated , Product data updated , Amazon.com / United States

What this page compares

See how Clorox 11010’s particle-responsive Auto stacks up against Honeywell HPA300’s smoke CADR, with room sizing, fan settings and filter care covered along the way.

Either one could serve as a local-control purifier for everyday airborne particles in a dry bedroom, den or living room. The choice can be pulled two ways. Your room might call for more maximum-speed particle capacity, while you might want the machine to adjust its own fan when particles rise. A bigger rating doesn't give you that control, and a sensor doesn't raise the rating.

Which one fits

Pick the situations that sound like you

  • Both maximum ratings meet my room target and I want fan changes triggered by particles

    HPA300 has no PM2.5 trigger, and Clorox does. Its 206 CFM maximum rating can be used to screen the room, though Auto does not maintain that flow. Place it somewhere dry, level and clear, with access to the filter, and away from grease, open fires and oil or chemicals.

    Clorox Large Room True HEPA
    Better fit
    Honeywell HPA300
    Caution
  • My smoke-CADR target is over 206 and at most 300 CFM, and Turbo is fine with me

    Only at its published maximum can HPA300 cover this sizing range, and that means switching to Turbo by hand since it starts on Low. You have to accept the noise and set it upright in a dry, unobstructed spot with access to the front filter and a direct wall outlet, away from damp areas and combustible fumes.

    Clorox Large Room True HEPA
    Not suitable
    Honeywell HPA300
    Better fit
  • Both maximum ratings meet my target, and I'll set a fixed speed by hand

    The two main advantages no longer break the tie. Look at output at the speed you will really use, placement, service access and the current complete offers. Fitting your room about equally doesn't mean equal noise, energy use or particle removal. And if you can only accept a low speed, neither maximum rating shows that speed meets the target.

    Clorox Large Room True HEPA
    Similar
    Honeywell HPA300
    Similar
  • I need a smoke CADR over 206 CFM plus automatic fan changes triggered by PM2.5

    Clorox responds to particles, but its maximum smoke rating tops out at 206 CFM. HPA300 gets to 300 CFM on manual Turbo yet has no PM2.5 Auto. If both requirements are firm, look for another verified model.

    Clorox Large Room True HEPA
    Not suitable
    Honeywell HPA300
    Not suitable
  • I need proof the required particle rate holds at a strict quiet setting

    Both the 206 and 300 CFM figures are maximum-speed ratings, and neither shows the output you need at a strict quiet setting. Before you buy, find measurements at that operating point, even if the panel can be darkened.

    Clorox Large Room True HEPA
    Caution
    Honeywell HPA300
    Caution
  • I need to extract grease or chemical fumes, or I can't keep the airflow path clear

    Neither works as a grease or chemical-fume extractor or as a hazardous-gas safeguard. Clorox prohibits use in greasy kitchens, near open fires and around oil or chemicals. Honeywell prohibits damp locations, combustible fumes and blocked grilles. Filtration is no substitute for source control, proper ventilation or a carbon-monoxide alarm.

    Clorox Large Room True HEPA
    Not suitable
    Honeywell HPA300
    Not suitable

In practice

Differences you will notice

A bigger room can make the extra capacity a requirement

Take an 18 by 20 by 8-foot room and a chosen target of five filtered-air changes per hour. That requires 240 CFM. HPA300 passes the sizing calculation on manual Turbo, and Clorox’s 206 CFM maximum does not. At 15 by 15 by 8 feet the same target drops to 150 CFM and both maximum ratings qualify, so capacity no longer decides alone. Neither example establishes quiet-speed output, ventilation or a health result.

How we worked this out

Published smoke CADR figures are compared here at maximum fan speed, and the room dimensions and five-change target are assumptions stated up front. Actual particle levels still depend on room mixing, open doors or windows, ongoing sources and the filters.

Automatic response can mean fewer trips to the controls

When both maximum ratings suit the room, Clorox will adjust its fan from the onboard PM2.5 reading while you are there, and Honeywell leaves that to you. If you already want a fixed manual speed, that convenience is moot. Auto can slow down, so a good display reading and the room-sizing calculation both fall short of proving continuous output or safety across the room.

How we worked this out

Clorox documents both PM2.5-triggered fan changes and manual selection. The exact HPA300 control sequence documents manual cleaning levels plus a separate Turbo. These are different ways of operating, and they have nothing to do with the published maximum capacity.

Some requirements eliminate both

If you need particle-triggered Auto and more than 206 CFM, neither works here. Clorox offers the trigger and Honeywell offers the higher manual-speed capacity. A target above 300 CFM is out of reach for both too. Loosening a control or room-size requirement may reopen the choice, but it cannot validate an unmeasured quiet setting or a prohibited location. Neither does grease extraction, chemical-fume control or hazardous-gas protection.

How we worked this out

Capacity, automatic response, sound at a chosen speed and permitted placement each stand alone as requirements. The sources available do not show any model that meets every combination.

Plug in your numbers

Can either purifier keep up with your room?

This checks hard limits only. Personal preferences are left out of the math.

Clorox Large Room True HEPA

Works with your numbers

206 CFM of verified clean-air delivery works out to about 5.2 air changes per hour in this room. Hitting the 5 ACH target takes 200 CFM.

Honeywell HPA300

Works with your numbers

300 CFM of verified clean-air delivery works out to about 7.5 air changes per hour in this room. Hitting the 5 ACH target takes 200 CFM.

This uses each model’s pollutant-specific CADR at top speed and a target of five air changes per hour. Quieter settings clean less air. Raw airflow and one-change coverage claims are never swapped in.

Option A
Clorox Large Room True HEPA

Clorox, 11010

Large Room True HEPA

Clorox 11010 has onboard PM2.5-responsive Auto and four speeds selected manually. The published maximum smoke CADR is 206 CFM, and Auto does not guarantee that output. The filter is reached from underneath, and greasy kitchens, open fires and oil or chemical areas are excluded.

Best for
You care about PM2.5-triggered fan changes, and 206 CFM at maximum speed covers your room target. Clorox’s Auto reacts to what the sensor reads. It does not guarantee maximum flow or monitor the safety of the whole room. Set it on a dry, level surface with clear airflow and room to reach the filter, away from greasy kitchens, open fires and oil or chemicals. Routine care still applies.

Facts we checked

  • Published smoke CADR at maximum speed: 206 cubic feet per minute
  • Who changes the fan when particles change: Auto follows its onboard PM2.5 sensor, or choose a manual speed
  • Darkening the panel: Separate Light button with On, Dim and Off
  • Reaching and servicing the filters: Unplug, disconnect the adapter and invert for bottom access
Option B
Honeywell HPA300

Honeywell, HPA300

HPA300

Honeywell HPA300 has a published maximum smoke CADR of 300 CFM, reached with Turbo selected manually. It starts on Low, so switching it on does not give maximum output. It needs a direct outlet and clear front access, and its nonwashable three-element HEPA set and prefilter get replaced.

Best for
Your smoke-CADR target is above 206 CFM but not above 300 CFM, and you are willing to switch the HPA300 to manual Turbo and live with the noise. Its Low startup setting does not reach that rating. Stand it upright in a dry spot with the grilles clear, the front accessible for filters and a direct wall outlet, away from damp locations and combustible fumes. You will still need to replace filters.

Facts we checked

  • Published smoke CADR at maximum speed: 300 cubic feet per minute
  • Who changes the fan when particles change: Choose a cleaning level and Turbo at the panel
  • Darkening the panel: Separate dimmer with High, Low and Off
  • Reaching and servicing the filters: Front grille access to three HEPA elements and a prefilter

Spec by spec

Where they really differ

Where Clorox Large Room True HEPA and Honeywell HPA300 differ
SpecClorox Large Room True HEPAHoneywell HPA300In practice
Published smoke CADR at maximum speed206 cubic feet per minute300 cubic feet per minuteSome room-volume targets are beyond Clorox’s maximum but within Honeywell’s. The comparison uses the same smoke-particle rating, not a total of smoke, dust and pollen. Neither value shows output at a lower speed, and you still need to check your actual room.
Who changes the fan when particles changeAuto follows its onboard PM2.5 sensor, or choose a manual speedChoose a cleaning level and Turbo at the panelWhen the sensor reading changes, Clorox adjusts its fan without you going back to the panel, while HPA300 needs someone to choose the level. That convenience does not prove Auto holds a chosen room-wide particle target or that it always runs at maximum speed.
Darkening the panelSeparate Light button with On, Dim and OffSeparate dimmer with High, Low and OffOn neither model does a dark panel force a lower fan speed. Clorox Auto can still change the fan because of particles. Turning the lights off is not the same as a tested quiet-airflow mode.
Reaching and servicing the filtersUnplug, disconnect the adapter and invert for bottom accessFront grille access to three HEPA elements and a prefilterLeave enough space to service the unit. Clorox calls for routine vacuum cleaning and, eventually, filter replacement. Honeywell’s filters are nonwashable consumables. A sensor or a larger rating does not make filter care optional.
Room and power requirementsLevel household placement away from grease, open fires, oil and chemicalsUpright, clear grilles and direct wall-outlet connectionLook at the installation before you compare capacity. Room-size marketing doesn't approve an enclosed shelf or a greasy kitchen. Honeywell must be plugged in without an extension cord or power strip and kept out of damp areas and combustible gases.

Trade-offs

What each pick costs you

With Clorox Large Room True HEPA

  • To get at the filter on the bottom, unplug the unit, disconnect the adapter and turn it upside down. Greasy kitchens, open fires and oil or chemical areas are off limits. Cleaning and replacement are still required.

With Honeywell HPA300

  • Keep the front clear for filter access and plug it straight into an outlet, with no extension or power strip. Its three Type R HEPA filters and Type A prefilter cannot be washed and must be replaced. Check the exact offer and which filters come with it.

Change of plan

When the answer changes

Fan changes triggered by particles matter, and 206 CFM meets the maximum-speed sizing target

Go with Clorox Large Room True HEPA. Clorox has PM2.5 Auto, but 206 CFM is its maximum and not something Auto guarantees. You still need a dry, clear location you can service, away from greasy kitchens, open fires and oil or chemicals.

The target is above 206 and at most 300 CFM, and picking Turbo manually is fine

Go with Honeywell HPA300. HPA300 reaches 300 CFM only on manual Turbo. Its startup Low setting falls short. You have to accept its sound and give it a dry, upright, open spot with front filter access and a direct wall outlet, away from damp areas and combustible fumes.

The target is beyond both ratings, or it calls for more than 206 CFM along with PM2.5 Auto

Neither model fits. Nothing here pairs PM2.5 Auto with a maximum smoke rating above 206 CFM, and neither product goes beyond 300 CFM. A smaller room or willingness to use manual Turbo changes your choice, but not the limits of either product.

Output at a quiet setting is unverified, or the planned location goes against the instructions

Neither model fits. Look for another verified setup if exact output at a quiet setting is essential or the airflow can't stay clear. Clorox rules out grease, open fires and oil or chemicals, and HPA300 rules out damp locations and combustible fumes. Neither gives hazardous-gas protection.

Decision guide

Before you buy

Do your room sizing with the fan speed you will really run. After that, weigh whether fan changes triggered automatically by particles matter more to you than the extra capacity at maximum speed.

Check these before you buy

  • Verify that the listing is the white US Clorox 11010 or the black US Honeywell HPA300, and check which filters come with it. The Clorox 11011 is a separate Alexa-enabled model, and the Honeywell HPA5300B is another model with different controls. Because the HPA300 manual also covers the smaller HPA090, HPA100 and HPA200, follow its HPA300 filter count and control instructions.
  • Look at the exact model in the current offer, plus the seller, condition, included filters and return terms. Honeywell Store lists its own HPA300 as discontinued, but that says nothing about production status across the manufacturer or whether another seller has stock. This comparison makes no claim about current price, availability, delivery or an extra-filter bundle.
  • The examples here all use smoke CADR. At the highest fan setting, Clorox publishes 206 CFM and Honeywell publishes 300 CFM. Dust ratings are 219 and 320 CFM respectively, and pollen ratings are 232 and 300 CFM. Do not add the three ratings together or put a dust figure in place of smoke. All of these describe particles and say nothing about gas removal.
  • Take an illustrative room that is 18 feet long, 20 feet wide and 8 feet high. Its volume is 2,880 cubic feet. With a chosen sizing target of five filtered-air changes per hour, you need 2,880 times 5 divided by 60, or 240 CFM. The HPA300’s published maximum smoke CADR is above that figure and the Clorox’s is not. Five is a comparison target chosen for this example. It is neither a medical threshold nor a guarantee of clean air. The math sizes filtered air and does not cover fresh-air ventilation.
  • In a second room that is 15 feet long, 15 feet wide and 8 feet high, the volume is 1,800 cubic feet. The same five-change target needs 1,800 times 5 divided by 60, or 150 CFM, which is under both maximum smoke ratings. Both units stay in the running, though this says nothing about how either performs at a lower speed. Results can shift with air mixing, room layout, open doors or windows, ongoing particle sources and filter condition. Neither example covers several connected rooms.
  • Turn the Clorox on and use the Fan button to select Auto. The sensor then picks a fan speed based on the measured PM2.5 level. A manual speed is available instead. The published maximum is neither an Auto average nor a guaranteed minimum. The onboard reading does not certify the air in the whole room as safe, and it is not a gas detector. The shared manual’s Wi-Fi and Alexa instructions apply to the 11011 only.
  • To run the HPA300 at its maximum speed, power it on and then choose Turbo, because the manual says it starts on Low. A second tap on Turbo goes back to the previous cleaning setting. Judge for yourself whether that operating sound is acceptable in the spot where it will sit. No matched noise measurements and no smoke CADR for quieter settings are part of this comparison.
  • If you want the panel dark, use the light controls, which are separate from the fan. The Clorox light has On, Dim and Off, and Honeywell’s dimmer can turn its lights off while the purifier keeps running. The Clorox 11010 has a 1, 4 or 8-hour shutoff and the HPA300 a 2, 4 or 8-hour shutoff. Leave the timer unset if you want continuous operation. Neither timer schedules a later start.
  • Set the Clorox on a level indoor surface with its air path unobstructed and away from water. It should not run in a greasy kitchen, near an open fire, or in a garage or any area with oil, solvents, insecticides or other chemicals. Use the adapter that comes with it. You also need room to unplug it, disconnect the adapter, turn it upside down and open the filter cover on the bottom. No numeric installed clearance is established here.
  • The HPA300 should stand upright on a firm, level, flat indoor surface. Point the front away from the nearest wall or furniture and leave every grille unblocked. Bathrooms, laundry areas and other damp locations are off limits, as are spots near combustible gases or vapors. Plug it straight into a working wall outlet, never an extension cord or power strip, and leave room to take off the front grille and pull the filters. Before you run it, strip the wrappers from all filters and the prefilter, put in all three Type R HEPA elements with the tabs facing out and fit the Type A prefilter at the front.
  • Start Clorox care by switching it off, unplugging it and disconnecting the adapter, and only then flip it over and open the bottom cover. Once a month, or more often if needed, vacuum the outside of the filter and the interior with a brush attachment. That is the documented cleaning method, so do not assume the filter can be washed with water. Detergent, solvents and spray cleaners are off the table. Look for clogging, reduced airflow or odors. The reminder appears after about 4,380 hours and asks you to inspect the filter. It does not mean you should throw it away automatically. The manual’s replacement guideline is a 6 to 12-month range, depending on condition. Use the specified 12010 replacement filter and reset the reminder once you have swapped it in.
  • Before opening the Honeywell’s front grille for care, switch it off and unplug it. Its filters cannot be washed. Inspect them from time to time. The Type A prefilter is due for replacement about every three months and the three Type R HEPA elements about every twelve months, though condition and use set the real interval. Do not breathe in the collected dust. After you replace a filter, reset its matching reminder. Keep the area around the unit clean and wipe the exterior with a dry cloth. Filter cost and the number of pieces alone do not tell you the total annual running cost.

What this page can’t tell you

  • The basis here is published particle ratings and operating instructions for the exact models. Noise, energy use, sensor accuracy, reliability, gas removal and health outcomes were not tested hands-on.
  • Every sizing example relies on the same smoke pollutant, maximum-speed ratings, explicit room volumes and a chosen five-change target. None of them guarantees whole-room performance, sets a safe-exposure threshold or calculates fresh-air ventilation.
  • There is no established smoke CADR for lower speeds or for Auto. A dark panel is no proof of quiet operation, and a light or sensor status does not mean all the air in the room has passed through the filter.
  • Filtering particles is no substitute for controlling the source, ventilating properly or having a carbon-monoxide alarm. Neither purifier addresses an active gas leak, combustible fumes or an installation that is not permitted. The page makes no claim of preventing or treating any medical condition.

By the numbers

What the data shows

What we found across the air purifiers we compare, plus the checked facts behind each finding.

Show the facts and the math
Models in the comparison
2 models
Sources
4 covering these models
Product data updated
The facts and sources behind each product in this recommendation
ProductNeeds it meetsFacts we checkedSources
Clorox Large Room True HEPA
  • You care about PM2.5-triggered fan changes, and 206 CFM at maximum speed covers your room target. Clorox’s Auto reacts to what the sensor reads. It does not guarantee maximum flow or monitor the safety of the whole room. Set it on a dry, level surface with clear airflow and room to reach the filter, away from greasy kitchens, open fires and oil or chemicals. Routine care still applies.
  • Published smoke CADR at maximum speed: 206 cubic feet per minute
  • Who changes the fan when particles change: Auto follows its onboard PM2.5 sensor, or choose a manual speed
  • Darkening the panel: Separate Light button with On, Dim and Off
  • Reaching and servicing the filters: Unplug, disconnect the adapter and invert for bottom access
  • Room and power requirements: Level household placement away from grease, open fires, oil and chemicals
Honeywell HPA300
  • Your smoke-CADR target is above 206 CFM but not above 300 CFM, and you are willing to switch the HPA300 to manual Turbo and live with the noise. Its Low startup setting does not reach that rating. Stand it upright in a dry spot with the grilles clear, the front accessible for filters and a direct wall outlet, away from damp locations and combustible fumes. You will still need to replace filters.
  • Published smoke CADR at maximum speed: 300 cubic feet per minute
  • Who changes the fan when particles change: Choose a cleaning level and Turbo at the panel
  • Darkening the panel: Separate dimmer with High, Low and Off
  • Reaching and servicing the filters: Front grille access to three HEPA elements and a prefilter
  • Room and power requirements: Upright, clear grilles and direct wall-outlet connection

Ready to buy

See today’s price and what owners say

Open either model on Amazon for the current price, customer reviews and delivery options.

Clorox Large Room True HEPA

Clorox Large Room True HEPA

You care about PM2.5-triggered fan changes, and 206 CFM at maximum speed covers your room target. Clorox’s Auto reacts to what the sensor reads. It does not guarantee maximum flow or monitor the safety of the whole room. Set it on a dry, level surface with clear airflow and room to reach the filter, away from greasy kitchens, open fires and oil or chemicals. Routine care still applies.

See price & reviews on Amazon
Honeywell HPA300

Honeywell HPA300

Your smoke-CADR target is above 206 CFM but not above 300 CFM, and you are willing to switch the HPA300 to manual Turbo and live with the noise. Its Low startup setting does not reach that rating. Stand it upright in a dry spot with the grilles clear, the front accessible for filters and a direct wall outlet, away from damp locations and combustible fumes. You will still need to replace filters.

See price & reviews on Amazon

Each link opens in a new tab.

We may earn a commission from qualifying Amazon purchases. How we make money