Side by side

Champion 201176 vs Westinghouse iGen12000TFc: Westinghouse supports larger natural-gas loads, and Champion weighs less

Quick verdict

Pick the lighter open-frame inverter, or pick the unit with the larger natural-gas running allowance.

Before you buy

Why, and what it costs you

A running load of 6,000W on natural gas

201176 shows -125W of nominal margin, against 1,200W for iGen12000TFc. A negative number means the continuous rating has been exceeded.

Where this comes from

The measured total running load is assumed to be 6000W on natural gas. Margin = fuel-specific running watts minus 6000. Starting transients, altitude, temperature, power factor and per-leg limits are left out.

The catch

Champion 9000-Watt Tri-Fuel Inverter with CO Shield

Weighing 156.6 pounds, it has to be wheeled and moved with care.

The catch

Westinghouse iGen12000TFc

A 50A-shaped outlet is not proof that the generator supplies 50A continuously at 240V.

Champion 9000-Watt Tri-Fuel Inverter with CO Shield

Champion 9000-Watt Tri-Fuel Inverter with CO Shield

Why pick it
  • On natural gas, your load stays under 5875W
  • Electric start with a recoil backup is what you want
The catch
Weighing 156.6 pounds, it has to be wheeled and moved with care.
See price & reviews on Amazon
Westinghouse iGen12000TFc

Westinghouse iGen12000TFc

Why pick it
  • Natural gas has to give you 7200W running
  • You want remote and electric start along with a recoil backup
The catch
A 50A-shaped outlet is not proof that the generator supplies 50A continuously at 240V.
See price & reviews on Amazon

We may earn a commission from qualifying Amazon purchases. How we make money

Comparison updated , Product data updated , Amazon.com / United States

What this page compares

A look at 201176 and iGen12000TFc on fuel-specific power, starting demand, voltage and connection limits, so you can choose a generator.

Pick the lighter open-frame inverter, or pick the unit with the larger natural-gas running allowance.

Which one fits

Pick the situations that sound like you

  • A continuous natural gas load of 6,000W

    That 9000W headline on the Champion is its starting output. On natural gas it runs at 5875W, which means a continuous 6000W plan is already beyond its rating.

    Champion 9000-Watt Tri-Fuel Inverter with CO Shield
    Not suitable
    Westinghouse iGen12000TFc
    Depends
  • Moving the generator and starting it when the power is out

    With an enclosed body and remote start, the Westinghouse delivers 7200W running on natural gas. Its weight is 191lb against 165.8lb for the Champion.

    Champion 9000-Watt Tri-Fuel Inverter with CO Shield
    Depends
    Westinghouse iGen12000TFc
    Depends
  • Hooking up the specified appliances or the home inlet

    Each is an inverter, and each needs a correctly sized fuel supply. Check natural-gas line capacity and regulator requirements at the installation itself, rather than inferring them from the generator’s peak number.

    Champion 9000-Watt Tri-Fuel Inverter with CO Shield
    Depends
    Westinghouse iGen12000TFc
    Depends
  • The larger inverter is 25.2lb heavier dry

    In exchange for 25.2lb of added weight, Westinghouse raises natural-gas running output by 1325W. Planning a rolling route and vehicle loading remains a separate issue.

    Champion 9000-Watt Tri-Fuel Inverter with CO Shield
    Depends
    Westinghouse iGen12000TFc
    Depends

In practice

Differences you will notice

A running load of 6,000W on natural gas

201176 shows -125W of nominal margin, against 1,200W for iGen12000TFc. A negative number means the continuous rating has been exceeded.

How we worked this out

The measured total running load is assumed to be 6000W on natural gas. Margin = fuel-specific running watts minus 6000. Starting transients, altitude, temperature, power factor and per-leg limits are left out.

A total starting event of 8,500W

Measured against this separately specified total starting demand, 201176 has 500W of published peak margin and iGen12000TFc has 1,300W.

How we worked this out

Take the combined load during one motor start as 8500W, counting the appliances already running. Subtract 8500 from the natural gas starting rating. That shows nothing about surge duration or whether the motor starts successfully.

The larger inverter is 25.2lb heavier dry

In exchange for 25.2lb of added weight, Westinghouse raises natural-gas running output by 1325W. Planning a rolling route and vehicle loading remains a separate issue.

How we worked this out

191 minus 165.8 = 25.2lb. 7200 minus 5875 = 1325W. Mass gives no basis for any runtime or acoustic result.

Plug in your numbers

Can either generator run what you need?

This checks hard limits only. Personal preferences are left out of the math.

What needs power when the grid goes down?

Champion 9000-Watt Tri-Fuel Inverter with CO Shield

Works with your numbers

On gasoline, it is rated for 7,250 running and 9,000 starting watts. With reserve, your load plan calls for 1,200 watts running and 2,900 watts starting.

Westinghouse iGen12000TFc

Works with your numbers

On gasoline, it is rated for 9,000 running and 12,000 starting watts. With reserve, your load plan calls for 1,200 watts running and 2,900 watts starting.

The estimate adds up the running watts of everything on at once, the biggest single startup surge and 15% headroom. Check each appliance label before you rely on it. Never run a fuel-burning generator indoors, in a garage or near doors, windows or vents.

Option A
Champion 9000-Watt Tri-Fuel Inverter with CO Shield

Champion, 201176

9000-Watt Tri-Fuel Inverter with CO Shield

On gasoline it delivers 7,250 running watts and 9,000 starting watts, and it also runs on propane and natural gas.

Best for
get a 240V well pump started and keep a window air conditioner running

Facts we checked

  • On gasoline its ratings are 7,250 running watts and 9,000 starting watts.
  • Gasoline, propane and natural gas can all fuel it.
  • Inverter power electronics produce its output.
Option B
Westinghouse iGen12000TFc

Westinghouse, iGen12000TFc

iGen12000TFc

This large enclosed tri-fuel inverter is rated 9000W running on gasoline with a 12000W peak. Both 14-50R and L14-30R connections are included, and continuous ratings are lower on gaseous fuels.

Best for
Bigger home loads you manage carefully, on inverter power

Facts we checked

  • Gasoline output of 9000W running and 12000W starting
  • Propane output of 8100W running and 11000W starting
  • Natural gas output of 7200W running and 9800W starting
  • Duplex 5-20R plus 120/240V 14-50R and L14-30R

Spec by spec

Where they really differ

Where Champion 9000-Watt Tri-Fuel Inverter with CO Shield and Westinghouse iGen12000TFc differ
SpecChampion 9000-Watt Tri-Fuel Inverter with CO ShieldWestinghouse iGen12000TFcIn practice
Running and starting output on natural gas5,875W running / 9,000W starting7,200W running / 9,800W startingEach of continuous load and brief starting demand has its own limit.
Starting systemElectric with recoil backupRemote and electric with recoil backupHow easy it is to start is a separate matter from how the generator is carried.
Handling layout165.8lb wheeled open frame191lb wheeled enclosureLook at the route out of storage and how it will get into a vehicle.
Connection panel120/240V L14-30R plus 120V household outlets120/240V 14-50R and L14-30R plus duplex 5-20RMatch the exact receptacle, breaker and cord to the system you intend.
Gasoline tank4.3 gallons7.9 gallonsRuntime at your load cannot be worked out from tank size alone.

Trade-offs

What each pick costs you

With Champion 9000-Watt Tri-Fuel Inverter with CO Shield

  • On natural gas it runs 1,375 watts lower than on gasoline, so size your load plan using the figures for whichever fuel you pick.

With Westinghouse iGen12000TFc

  • Ratings are lower on propane or natural gas. Look at the running load and the motor starting demand on their own.

Change of plan

When the answer changes

On natural gas, your load stays under 5875W

Go with Champion 9000-Watt Tri-Fuel Inverter with CO Shield. That 9000W headline on the Champion is its starting output. On natural gas it runs at 5875W, which means a continuous 6000W plan is already beyond its rating.

You need 7200W of running power on natural gas

Go with Westinghouse iGen12000TFc. With an enclosed body and remote start, the Westinghouse delivers 7200W running on natural gas. Its weight is 191lb against 165.8lb for the Champion.

Decision guide

How to decide

Go light with the open-frame inverter, or go for the bigger natural-gas running allowance.

01

Anchor the load list to your fuel

That 9000W headline on the Champion is its starting output. On natural gas it runs at 5875W, which means a continuous 6000W plan is already beyond its rating.

02

What it is like to own each one

With an enclosed body and remote start, the Westinghouse delivers 7200W running on natural gas. Its weight is 191lb against 165.8lb for the Champion.

03

Installation and connection to verify

Each is an inverter, and each needs a correctly sized fuel supply. Check natural-gas line capacity and regulator requirements at the installation itself, rather than inferring them from the generator’s peak number.

Check these before you buy

  • Collect the real running watts, then check the largest starting demand when loads start together.
  • Run fuel supply, voltage, receptacle, cord, neutral bonding and transfer equipment past a qualified electrician for confirmation.
  • Keep it outdoors and 20 feet or more from doors, windows and vents, and aim the exhaust away. Do not backfeed any wall outlet.

What this page can’t tell you

  • This is calculated from the specification sheets, with no measured generator or motor-start tests behind it.
  • Your usable output may shrink under the effect of altitude, temperature, fuel supply and individual 120V leg limits.
  • CO shutoff is not a safeguard that makes indoor, garage or enclosed-shelter use acceptable.

By the numbers

What the data shows

What we found across the generator sets we compare, plus the checked facts behind each finding.

How many fit

Only 2 of the 24 models checked meet every need here: “Power a refrigerator and the essential lights” and “Tie in through a transfer switch at home”.

2 models fit, out of 24 checked
Show the facts and the math
Models in the comparison
24 models
Sources
4 covering these models
Product data updated

How we countedThe count uses each product's current fit ratings for “Power a refrigerator and the essential lights” and “Tie in through a transfer switch at home”. A need with no documented match is not counted.

The facts and sources behind each product in this recommendation
ProductNeeds it meetsFacts we checkedSources
Champion 9000-Watt Tri-Fuel Inverter with CO Shield
  • Keep a refrigerator and essential
  • Connect through a home transfer
  • On gasoline its ratings are 7,250 running watts and 9,000 starting watts.
  • Gasoline, propane and natural gas can all fuel it.
  • Inverter power electronics produce its output.
Westinghouse iGen12000TFc
  • Connect through a home transfer
  • Gasoline output of 9000W running and 12000W starting
  • Propane output of 8100W running and 11000W starting
  • Natural gas output of 7200W running and 9800W starting