The catch
Westinghouse iGen12000TFc
A 50A-shaped outlet is not proof that the generator supplies 50A continuously at 240V.
Side by side
Pick inverter operation, or pick the open-frame model for its higher natural-gas output.
Before you buy
iGen12000TFc shows -800W of nominal margin, against 1,500W for WGen11500TFc. A negative number means the continuous rating has been exceeded.
Where this comes from
The measured total running load is assumed to be 8000W on natural gas. Margin = fuel-specific running watts minus 8000. Starting transients, altitude, temperature, power factor and per-leg limits are left out.
The catch
A 50A-shaped outlet is not proof that the generator supplies 50A continuously at 240V.
The catch
Plan for two people to lift the 230-pound frame, and for level roll-out storage.


We may earn a commission from qualifying Amazon purchases. How we make money
See how iGen12000TFc stacks up against WGen11500TFc on fuel-specific power, starting demand, voltage and connection limits when choosing a generator.
Pick inverter operation, or pick the open-frame model for its higher natural-gas output.
Which one fits
Planning for 8000W continuous on natural gas goes beyond the iGen12000TFc’s 7200W rating. The WGen11500TFc offers 9500W on natural gas, so its higher fuel-specific capacity matters here.
Under 3% THD is specified for the iGen12000TFc, an inverter. The WGen11500TFc is a conventional generator with 5% or less THD. Check what each sensitive load requires instead of lumping all conventional generators together.
14-50R and L14-30R sockets are on both. Current limits still depend on fuel output and individual breakers, and a bigger generator does not remove the need to manage loads.
A balanced 50A load at 240V comes to 12000W. That is 4800W over the continuous natural-gas rating for iGen12000TFc and 2500W over it for WGen11500TFc.
In practice
iGen12000TFc shows -800W of nominal margin, against 1,500W for WGen11500TFc. A negative number means the continuous rating has been exceeded.
The measured total running load is assumed to be 8000W on natural gas. Margin = fuel-specific running watts minus 8000. Starting transients, altitude, temperature, power factor and per-leg limits are left out.
Measured against this separately specified total starting demand, iGen12000TFc has -200W of published peak margin and WGen11500TFc has 2,000W.
Take the combined load during one motor start as 10000W, counting the appliances already running. Subtract 10000 from the natural gas starting rating. That shows nothing about surge duration or whether the motor starts successfully.
A balanced 50A load at 240V comes to 12000W. That is 4800W over the continuous natural-gas rating for iGen12000TFc and 2500W over it for WGen11500TFc.
240 × 50 = 12000W. Subtract each natural-gas running rating from it. An inlet rating is a ceiling on the connection and not a promised generator output.
Plug in your numbers
This checks hard limits only. Personal preferences are left out of the math.
On gasoline, it is rated for 9,000 running and 12,000 starting watts. With reserve, your load plan calls for 1,200 watts running and 2,900 watts starting.
On gasoline, it is rated for 11,500 running and 14,500 starting watts. With reserve, your load plan calls for 1,200 watts running and 2,900 watts starting.
The estimate adds up the running watts of everything on at once, the biggest single startup surge and 15% headroom. Check each appliance label before you rely on it. Never run a fuel-burning generator indoors, in a garage or near doors, windows or vents.

Westinghouse, iGen12000TFc
This large enclosed tri-fuel inverter is rated 9000W running on gasoline with a 12000W peak. Both 14-50R and L14-30R connections are included, and continuous ratings are lower on gaseous fuels.

Westinghouse, WGen11500TFc
Gasoline output is 11,500 running watts and 14,500 starting watts, and propane and natural gas work as fuels too.
Spec by spec
| Spec | Westinghouse iGen12000TFc | Westinghouse WGen11500TFc Tri-Fuel Generator | In practice |
|---|---|---|---|
| Running and starting output on natural gas | 7,200W running / 9,800W starting | 9,500W running / 12,000W starting | Each of continuous load and brief starting demand has its own limit. |
| Handling layout | 191lb wheeled enclosure | 230lb wheeled open frame | Look at the route out of storage and how it will get into a vehicle. |
| Connection panel | 120/240V 14-50R and L14-30R plus duplex 5-20R | 120/240V 14-50R and L14-30R plus two duplex 5-20R outlets | Match the exact receptacle, breaker and cord to the system you intend. |
| Gasoline tank | 7.9 gallons | 9.5 gallons | Runtime at your load cannot be worked out from tank size alone. |
| Power regulation | Inverter, Under 3% | Conventional, 5% or less | Check waveform requirements specific to the load. |
Trade-offs
Change of plan
Go with Westinghouse iGen12000TFc. Planning for 8000W continuous on natural gas goes beyond the iGen12000TFc’s 7200W rating. The WGen11500TFc offers 9500W on natural gas, so its higher fuel-specific capacity matters here.
Go with Westinghouse WGen11500TFc Tri-Fuel Generator. On natural gas, WGen11500TFc supplies up to 9500W continuously and iGen12000TFc stops at 7200W. Starting surge, fuel supply, wiring and appliance waveform limits still need to be checked.
Decision guide
Take inverter operation, or the open-frame model for its higher natural-gas output.
Planning for 8000W continuous on natural gas goes beyond the iGen12000TFc’s 7200W rating. The WGen11500TFc offers 9500W on natural gas, so its higher fuel-specific capacity matters here.
Under 3% THD is specified for the iGen12000TFc, an inverter. The WGen11500TFc is a conventional generator with 5% or less THD. Check what each sensitive load requires instead of lumping all conventional generators together.
14-50R and L14-30R sockets are on both. Current limits still depend on fuel output and individual breakers, and a bigger generator does not remove the need to manage loads.
By the numbers
What we found across the generator sets we compare, plus the checked facts behind each finding.
Only 2 of the 24 models checked meet every need here: “Power a refrigerator and the essential lights” and “Tie in through a transfer switch at home”.
2 models fit, out of 24 checkedHow we countedThe count uses each product's current fit ratings for “Power a refrigerator and the essential lights” and “Tie in through a transfer switch at home”. A need with no documented match is not counted.
| Product | Needs it meets | Facts we checked | Sources |
|---|---|---|---|
| Westinghouse iGen12000TFc |
|
|
|
| Westinghouse WGen11500TFc Tri-Fuel Generator |
|
|
Ready to buy
Open either model on Amazon for the current price, customer reviews and delivery options.

Inverter output and a lighter enclosed body appeal to you
See price & reviews on Amazon
Your running load on natural gas goes past 7200W
See price & reviews on AmazonEach link opens in a new tab.