The catch
Westinghouse WGen11500TFc Tri-Fuel Generator
Plan for two people to lift the 230-pound frame, and for level roll-out storage.
Side by side
Go for more natural-gas capacity, or for EFI fuel metering.
Before you buy
Nominal margin is 1,000W for WGen11500TFc and -1,000W for WGen9500TFc EFI. A negative number means the continuous rating has been exceeded.
Where this comes from
The measured total running load is assumed to be 8500W on natural gas. Margin = fuel-specific running watts minus 8500. Starting transients, altitude, temperature, power factor and per-leg limits are left out.
The catch
Plan for two people to lift the 230-pound frame, and for level roll-out storage.
The catch
Because published output differs by fuel, the row for your chosen fuel is the one the tool should use.


We may earn a commission from qualifying Amazon purchases. How we make money
WGen11500TFc and WGen9500TFc EFI side by side on fuel-specific power, starting demand, voltage and connection limits, to guide your generator choice.
Go for more natural-gas capacity, or for EFI fuel metering.
Which one fits
On natural gas, the WGen11500TFc gives 2000W more continuous output than the WGen9500TFc EFI. A plan for 8500W fits the first rating and goes 1000W over the second.
Westinghouse publishes THD at 5% or less for the WGen11500TFc and 23% or less for the WGen9500TFc EFI. Verify what power the connected electronics and controls require.
Remote start, 240V outlets and all three fuels come with both. EFI is a difference in starting and fuel metering, and it does not replace checking waveform and power ratings.
That figure is over the 31.25A natural-gas running equivalent of WGen9500TFc EFI and under the 39.6A equivalent of WGen11500TFc.
In practice
Nominal margin is 1,000W for WGen11500TFc and -1,000W for WGen9500TFc EFI. A negative number means the continuous rating has been exceeded.
The measured total running load is assumed to be 8500W on natural gas. Margin = fuel-specific running watts minus 8500. Starting transients, altitude, temperature, power factor and per-leg limits are left out.
Measured against this separately specified total starting demand, WGen11500TFc has 1,500W of published peak margin and WGen9500TFc EFI has -1,000W.
Take the combined load during one motor start as 10500W, counting the appliances already running. Subtract 10500 from the natural gas starting rating. That shows nothing about surge duration or whether the motor starts successfully.
That figure is over the 31.25A natural-gas running equivalent of WGen9500TFc EFI and under the 39.6A equivalent of WGen11500TFc.
8500 ÷ 240 = 35.42A. 7500 ÷ 240 = 31.25A. 9500 ÷ 240 = 39.58A. The load is assumed balanced, with power factor 1.0.
Plug in your numbers
This checks hard limits only. Personal preferences are left out of the math.
On gasoline, it is rated for 11,500 running and 14,500 starting watts. With reserve, your load plan calls for 1,200 watts running and 2,900 watts starting.
On gasoline, it is rated for 9,500 running and 12,500 starting watts. With reserve, your load plan calls for 1,200 watts running and 2,900 watts starting.
The estimate adds up the running watts of everything on at once, the biggest single startup surge and 15% headroom. Check each appliance label before you rely on it. Never run a fuel-burning generator indoors, in a garage or near doors, windows or vents.

Westinghouse, WGen11500TFc
Gasoline output is 11,500 running watts and 14,500 starting watts, and propane and natural gas work as fuels too.

Westinghouse, WGen9500TFc EFI
Rated at 9,500 running watts and 12,500 starting watts on gasoline, it also accepts propane and natural gas.
Spec by spec
| Spec | Westinghouse WGen11500TFc Tri-Fuel Generator | Westinghouse WGen9500TFc EFI Tri-Fuel Generator | In practice |
|---|---|---|---|
| Running and starting output on natural gas | 9,500W running / 12,000W starting | 7,500W running / 9,500W starting | Each of continuous load and brief starting demand has its own limit. |
| Starting system | Remote and electric with recoil backup | Remote and electric with EFI | How easy it is to start is a separate matter from how the generator is carried. |
| Handling layout | 230lb wheeled open frame | 222lb wheeled open frame | Look at the route out of storage and how it will get into a vehicle. |
| Gasoline tank | 9.5 gallons | 6.6 gallons | Runtime at your load cannot be worked out from tank size alone. |
| Power regulation | Conventional, 5% or less | Conventional, 23% or less | Check waveform requirements specific to the load. |
Trade-offs
Change of plan
Go with Westinghouse WGen11500TFc Tri-Fuel Generator. On natural gas, the WGen11500TFc gives 2000W more continuous output than the WGen9500TFc EFI. A plan for 8500W fits the first rating and goes 1000W over the second.
Go with Westinghouse WGen9500TFc EFI Tri-Fuel Generator. Westinghouse publishes THD at 5% or less for the WGen11500TFc and 23% or less for the WGen9500TFc EFI. Verify what power the connected electronics and controls require.
Decision guide
More natural-gas capacity or EFI fuel metering is the decision.
On natural gas, the WGen11500TFc gives 2000W more continuous output than the WGen9500TFc EFI. A plan for 8500W fits the first rating and goes 1000W over the second.
Westinghouse publishes THD at 5% or less for the WGen11500TFc and 23% or less for the WGen9500TFc EFI. Verify what power the connected electronics and controls require.
Remote start, 240V outlets and all three fuels come with both. EFI is a difference in starting and fuel metering, and it does not replace checking waveform and power ratings.
By the numbers
What we found across the generator sets we compare, plus the checked facts behind each finding.
Only 2 of the 24 models checked meet every need here: “Power a refrigerator and the essential lights” and “Tie in through a transfer switch at home”.
2 models fit, out of 24 checkedWestinghouse WGen11500TFc Tri-Fuel Generator lists 11,500 W for running-watt rating, 21% more than the 9,500 W on Westinghouse WGen9500TFc EFI Tri-Fuel Generator.
How we countedThe count uses each product's current fit ratings for “Power a refrigerator and the essential lights” and “Tie in through a transfer switch at home”. A need with no documented match is not counted.
How we calculatedFigures are for the named configuration on its main listed fuel. Output can drop on propane or natural gas. For context, 20 of 24 models publish comparable figures.
| Product | Needs it meets | Facts we checked | Sources |
|---|---|---|---|
| Westinghouse WGen11500TFc Tri-Fuel Generator |
|
| |
| Westinghouse WGen9500TFc EFI Tri-Fuel Generator |
|
|
Ready to buy
Open either model on Amazon for the current price, customer reviews and delivery options.

Lower published THD and 9500W running on natural gas are what you need
See price & reviews on Amazon
Your load fits within 7500W and you rank EFI highly
See price & reviews on AmazonEach link opens in a new tab.